Output Voltage 0-20 kVDC, ±10% for each polarity on an individual AeroBar; positive or negative output levels can be adjusted separately with IR Handheld Remote
Operating Mode Pulsed DC, steady-state DC or standby
All parameters are held within the AeroBar; no controller required
Fully adjustable parameters for each AeroBar utilizing Pulsed DC or Steady-state DC modes
Several AeroBar lengths including three lengths specifically designed for EFEMs
Discharge1 25 sec or less for ±1000V to ±100V discharge @ 24” with min 60 fpm airflow
Balance
±50V @ 24” measured directly below two opposite polarity emitter points (Model 5685 must be mounted at least 6” away from grounded surfaces for optimum balance performance)
IsoStat® technology
Steady-state DC ion emission for high ion density
Single-crystal silicon or titanium emitter points
Multiple lengths, including short 11 inch AeroBars
Balance <±25V over the length of the bar; maintains balance performance >6 months without cleaning (in an ISO 14644 Class 4 or better environment)
Performance 3.5 sec decay average @ 600 mm (typ) measured at 5711 AeroBar center and 25 mm straight air jet spacing, 18 l/m purging air, (250 mm long AeroBar), no laminar flow; setting 1 Hz, 100% output, CPM: balance <±10V; swing 100V pk-pk