Gow-Mac GC 5900

  • Series 5900 DID trace gas analysis gas chromatograph.
  • GOW-MAC® discharge ionization detector (DID) which is nonradioactive,universal, and concentration dependent.
  • The DID exhibits a dynamic range of < 5 ppb to < 0.5% by volume.
  • Numerous configurations, each having a unique valving and flow system to accomplish a variety of trace impurity gas applications.
  • Linear temperature range is ambient to 300 °C.
  • Powerful Clarity® chromatography software and a variety of interactive PC chromatography data software packages are available.

Gow-Mac GC 580

  • Series 580 isothermal gas chromatograph.
  • Thermal Conductivity Detectors.
  • Flame Ionization Detector (FID).
  • Discharge Ionization Detector (DID).
  • Flame Photometric Detector (FPD).
  • FID Electrometer Amplifier.

Gow-Mac 2400

  • Total hydrocarbon analyser.
  • Flame Ionization Detector (FID).
  • Methanizer to measure CO and CO2.
  • High resolution graphical LCD touchscreen.
  • Flameout indicator / Auto shutoff for gases.
  • Auto ranging from 0.00 ppm to 10,000 ppm.
  • Auto zero and calibration.
  • Programmable relays for concentration alarms.
  • Electronic flow control of air, fuel, and sample gas.
  • Real-time data logging by USB and serial port.
  • Outputs: Analog (standard): 4-20 mA, VDC [0-5 V] or Digital (optional): RS-232.

Gow-Mac 1400

  • Trace H2O in Ar analyzer.
  • Guaranteed 10 ppb sensitivity.
  • Measuring system based on spectral emission of argon plasma.
  • Exceptional detector performance by utilizing patented electro-optical modulation.
  • Cannot “blind” the instrument.
  • On-line continuous analysis
  • Fast response.
  • Recovers quickly from high moisture levels.
  • No permanent degradation of detector due to high moisture levels.
  • Extreme periods of acute dryness will not affect response or detector.
  • No valves, columns, or carrier gas.
  • No radioactive source.
  • No sensor or detector to replace.

Gow-Mac 1300

  • Trace N2 in He analyzer.
  • Guaranteed 10 ppb sensitivity.
  • Measuring system based on spectral emission of helium plasma.
  • Exceptional detector performance by utilizing patented electro-optical modulation.
  • On-line continuous trending.
  • Fast response…Fast recovery.
  • 4-20 mA output.
  • Dry contacts for over range indication.
  • Dry contacts for range selection indication.
  • No valves, columns, or carrier gas.
  • No radioactive source.
  • No sensor or detector to replace.
  • Maintenance free.
  • 19” rack mount or bench top.

Gow-Mac 1200

  • Trace N2 in Ar analyzer.
  • Guaranteed 10 ppb sensitivity.
  • Measuring system based on spectral emission of argon plasma.
  • Exceptional detector performance by utilizing patented electro-optical modulation.
  • On-line continuous trending.
  • Fast response…Fast recovery.
  • 4-20 mA output.
  • Dry contacts for over range indication.
  • Dry contacts for range selection indication.
  • No valves, columns, or carrier gas.
  • No radioactive source.
  • No sensor or detector to replace.
  • Maintenance free.
  • 19” rack mount or bench top.

Gow-Mac 210 Sulphur

  • Sulfur Analyzer meets ISBT Method 14 General Requirements and Guidelines for selective measurement of Total Sulfur Content (TSC) in beverage-grade CO₂.
  • Flame Photometric Detector (FPD) and proprietary technology is used for the sulphur measurement without interference from other potential impurities in CO₂.
  • The detector exhibits linearity over three orders of magnitude, with a detection limit of < 5ppb COS.
  • Rugged, simple to use, low maintenance.
  • Batch or continuous stream monitoring.
  • Automatic, hands-free calibration, flow setting and analysis.

Gow-Mac 210 BTEX

  • Highly selective for BTEX ( Benzene, Toluene, Ethyl benzene, o-Xylene, m-Xylene, and p-Xylene ) that meets all ISBT Method 12 criteria for selective measurement of benzene in CO2.
  • Using flame ionization detector (FID) and proprietary technology for the specific measurement of acetaldehyde without interference from other potential impurities in beverage-grade CO2.
  • The detector exhibits linearity over three orders of magnitude, with detection limits for BTEX of < 5 ppb, far below the ISBT specification of 20 ppb.
  • Automatic, hands-free calibration, flow setting and analysis.
  • Rack mount or bench-top.

Gow-Mac 210 Aromatic

  • Highly selective for benzene that meets all ISBT Method 12 criteria for selective measurement of benzene in CO2.
  • The detector exhibits linearity over three orders of magnitude, with detection limits for benzene of < 5 ppb, far below the ISBT specification of 20 ppb.
  • Rugged, simple to use, low maintenance.
  • Batch or continuous stream monitoring.
  • Automatic, hands-free calibration, flow setting and analysis.
  • Rack mount or bench-top.

Gow-Mac 210 ACE

  • Highly selective for acetaldehyde in CO2 gas background.
  • Using flame ionization detector (FID) and proprietary technology for the specific measurement of acetaldehyde without interference from other potential impurities in beverage-grade CO2.
  • Rugged, simple to use, low maintenance.
  • Batch or continuous stream monitoring.
  • Automatic, hands-free calibration, flow setting and analysis.
  • Rack mount or bench-top.